| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | xiangrui |
| Model Number : | TDL4-T |
| Certification : | CE |
| Price : | negotiable |
| Payment Terms : | L/C, D/A, D/P, T/T, Western Union |
| Delivery Time : | 5-8 work days |
TDL4-T Desktop Low Temperature Fully Automatic Decapping Centrifuge Refrigerated Type
Main technical performance
TDL4-T desktop low temperature fully automatic decapping centrifuge
vacuum blood collection tube automatically decaps, the decapping
success rate is 100%
The TDL4-T desktop low-temperature fully automatic decapping
centrifuge is suitable for capping vacuum blood collection tubes in
three lengths: 106/101/81mm.
The TDL4-T desktop low-temperature fully-automatic decapping
centrifuge has a large screen and true color display, a humanized
operation interface, and is simple and convenient to use.
The TDL4-T desktop low-temperature fully automatic decapping
centrifuge has real-time reading conversion and setting between
rpm/RCF, which is convenient and fast.
The TDL4-T desktop low-temperature fully automatic decapping
centrifuge uses imported high-performance compressor fluorine-free
refrigerant R404a, which meets environmental protection
requirements and has good refrigeration effect.
The TDL4-T desktop low-temperature fully automatic decapping
centrifuge adopts an electronic door lock, which is safe and
reliable.
The TDL4-T desktop low-temperature fully-automatic decapping
centrifuge adopts a special shock-absorbing structure with good
shock-absorbing effect and has an automatic balancing function.
The TDL4-T desktop low-temperature fully automatic decapping
centrifuge is equipped with multiple protection functions such as
unbalance, overspeed, and door cover protection.
TDL4-T desktop low-temperature fully automatic decapping centrifuge
has a maximum speed of 6000r/min and a maximum capacity of 4x750ml
The main technical parameters
| Model | TDL4-T |
| Maximum speed | 6000r/min |
| Maximum relative centrifugal force | 6060xg |
| Maximum capacity | 4x750ml |
| Speed accuracy | ± 10r/min |
| Time setting range | 1min~999min |
| Temperature setting range | -20~+40℃ |
| Temperature control accuracy | ±1℃ |
| Overall machine noise | ≤58dB(A) |
| Application areas | hospitals, blood stations, radioimmunoassay, nuclear medicine and other units |
| Overall dimensions (LxWxH) | 730mmx650mmx390mm |
| Net weight | 115Kg |
Adapted rotor parameters
| Rotor number | Rotor type | Rotor capacity | Maximum speed | Max RCF | Adapter can be added |
| 1 | horn rotor | 12x15ml | 6000r/min | 6060xg | 10/5ml |
| 2 | horizontal uncapping rotor | 48x5/3/2ml | 4000r/min | 3180xg | |
| 3 | horizontal uncapping rotor | 64x5/3/2ml | 4000r/min | 3190xg | |
| 4 | horizontal uncapping rotor | 80x5/3/2ml | 4000r/min | 3190xg | |
| 5 | horizontal uncapping rotor | 96x5/3/2ml | 4000r/min | 3360xg | |
| 6 | horizontal uncapping rotor | 4x750/500ml | 4000r/min | 3580xg | 250/100/50/10/5ml |
|